8 9
Wiring Diagrams Normal, Secure & Master Users
SA1DK
SA1DK
BL-D40
Wiring the Lock Strike Relay and REX
Wiring the BL-D40 External Sounder
TheSA1DKacceptsupto500usersandprovidesentryviatheuseofPINcodes.Eachuseris
providedwithtwocodememoryslots,MemorySlot1(PrimaryCode)andMemorySlot2(Secondary
Code).
Thewayinwhichthetwomemoryslotsareprogrammeddeterminesausersaccesslevelandalso
determinesthewayinwhichtheSA1DKgrantsaccessinitsthreeModesofOperation.
There are three user levels:
Normal User
ANormalUseronlyhasaPrimaryCodeandisonlygrantedaccesswhentheSA1DK
isinNormalorBypassMode.
Secure User
ASecureUsermusthaveaPrimaryandSecondaryCodeprogrammed,thetwocodes
mustnotbethesame.TheSecureUsercangainaccesswhentheSA1DKisinanyof
itsthreeModesofOperation.InNormalModetheSecureUsermustusetheirPrimary
Codetogainentry.InSecureModetheSecureusermustpresentboththeirPrimary
andSecondaryCodesinordertogainentry.
Master User
AMasterUsermusthavebothPrimaryandSecondaryCodesprogrammedwiththe
samePINcode.TheMasterUsercangainaccessduringanyModeofOperationby
presentingtheirPINcodetothecontroller.(TheMasterUserisconvenientbutisless
securethanaSecureUser).